Energy storage (regenerative fuel cells and batteries)
Electrolyser
Splits water into hydrogen and oxygen using daytime power, and pumps the gases up to storage pressure inside the stack.
- PEM electrolyser stack with reinforced membrane
- High-pressure water feed pump
- Hydrogen and oxygen water separators
- Water recirculation pump
- Stack pressure enclosure
Fuel cell stack
Recombines hydrogen and oxygen into water and electricity during shadow.
- PEM fuel cell stack, non-flow-through
- Passive internal water separation
- Auxiliary cell for product-water degassing
- Reactant pressure regulators
- Stack voltage monitor
Reactant storage
Holds the hydrogen and oxygen between charge and discharge.
- Spherical hydrogen tanks
- Spherical oxygen tanks
- Tank heaters (keep above 4 °C)
- Latching valves
- Pressure and temperature sensors
- Hydrogen leak detectors
Water management
Collects product water and keeps it clean enough to electrolyse again.
- Product water tank
- Deionising bed
- Water quality sensor
- Make-up water link to M06 water plant
- Freeze protection
Thermal control
Removes stack waste heat by day and keeps water and gas lines warm in the dark.
- Coolant pump loop
- Heat exchangers
- Radiator panel
- Insulated enclosure (MLI)
- Heaters
Li-ion battery modules
Cover fast load steps, fuel cell warm-up and reactor start-up.
- Commercial 18650 cells (LG MJ1 class)
- Battery management electronics
- Spare string
- Module heaters
- Heated enclosure
Power electronics and control
Connects storage to the grid and runs the system without people.
- Bidirectional DC–DC converter to the 120 VDC microgrid
- Small flight computer (CubeSat class)
- Safe-state logic
- Telemetry link
What it does
Storage covers the hours when no sunlight reaches the towers and the reactor alone is not enough. It also covers the years before the reactor arrives. Polar shadows last up to about 100 hours1. A regenerative fuel cell (RFC) stores more energy per kilogram than batteries: 320–650 Wh/kg against about 160 Wh/kg for packaged Li-ion1. Batteries stay in the system for fast peaks.
How it works
- Charge. By day, a PEM electrolyser splits water. The stack compresses its own gases, so no separate compressor is needed2.
- Discharge. In shadow, a PEM fuel cell recombines the gases into water and electricity. Making the fuel cell large and running it at low current density gives the best efficiency without much extra mass3.
- Tanks. In large systems, gas storage is nearly 60% of RFC mass3. Spherical tanks raise specific energy by about 50%3. In NASA’s equator study, cryogenic storage dropped efficiency below 15%, so gas storage is used3.
- Pressure. Lower electrolyser pressure raises efficiency. Going from 4,000 to 2,000 psia gains 3–5 points. Above ~2,000 psia, hydrogen leaking into the oxygen nears the flammability limit3.
- Losses. For a 50 kW RFC, parasitic loads during discharge add up to about 3.9 kW. Power electronics take 2.5 kW, tank heaters 0.7 kW, and pumps and valves the rest3. The model keeps the tanks above 4 °C3.
- Batteries. NASA’s fission concept used a 4 kWh pack of commercial cells at about 173 Wh/kg, with a spare string5. The best low-temperature Li-ion cells work only down to −60 °C and need heaters in shadow6.
Sizing
| Step | Arithmetic | Result |
|---|---|---|
| Net energy needed | 30 kW × 100 h (M04 design case) | 3.0 MWh |
| Fuel cell gross output | 3.0 MWh + ~8% parasitics3 | ~3.24 MWh |
| Energy per kg of water (ESTIMATE) | 2 × 96,485 C/mol7 × 0.8 V cell = 42.9 Wh/mol; × 55.5 mol/kg | ~2.38 kWh/kg |
| Water cycled | 3.24 MWh ÷ 2.38 kWh/kg | ~1.36 t |
| Hydrogen / oxygen | 2/18 and 16/18 of the water | ~152 kg H₂ / ~1.21 t O₂ |
| Tank volume at 12.4 MPa, 20 °C (ESTIMATE, ideal gas, +7% for H₂) | H₂ ~16 m³; O₂ ~7.4 m³ | ~24 m³ |
| Charge energy | 3.0 MWh ÷ 0.35 round-trip3 | ~8.6 MWh |
| Recharge power (ESTIMATE) | 8.6 MWh over 200–300 h of sun | ~29–43 kW |
| RFC system mass | 3 MWh ÷ 320–650 Wh/kg1 | 4.6–9.4 t |
| Same energy in Li-ion | 3 MWh ÷ 160 Wh/kg1 | ~19 t |
| Li-ion peak buffer (plan design) | 100 kWh ÷ 160 Wh/kg | ~0.6 t |
Modelled south-pole efficiency is 34.8% for a 10 kW RFC and 36.6% at 50 kW. Above about 25 kW there is little gain, so two 25 kW units give redundancy at almost no cost in efficiency3. With a 50% round-trip efficiency, the solar array must make about 3 times the RFC’s output power4.
Testing and qualification
- Done. NASA Glenn’s breadboard RFC ran autonomously for more than 550 hours of simulated lunar cycles, at balanced pressures up to 12.4 MPa. It ran open-loop (bottled gas in, products vented) and had five unplanned safe-state stops2.
- Closed-loop breadboard. Store and reuse the same gas and water for many simulated cycles, with no venting.
- 5–25 kW engineering unit. Test in thermal vacuum with flight-like tanks, at the cold sink temperatures of the chosen site.
- Tank sharing test. Run the RFC with water from an ISRU simulant loop (M06) to check membrane life.
- On the Moon. Start with a single 25 kW module carrying only non-essential loads. Move essential loads onto it after a full year without faults.
Open questions
- Can fission off-peak power do most of the recharging, so the solar towers don’t need to grow?
- Can dry gas tanks sit at lunar shadow temperatures instead of being heated above 4 °C?
- What membrane thickness and pressure give the best balance for this base’s duty cycle?
- How long do PEM stacks last over thousands of lunar charge cycles?
- Could cryogenic oxygen from the M06 plant replace part of the oxygen tankage?
| Severity | Problem | Solution |
|---|---|---|
| Critical | Low round-trip efficiency (~35% at the pole): every 1 kWh delivered needs about 3 kWh of daytime power. | Recharge mainly from fission off-peak power; size solar for recharge; choose lower electrolyser pressure and better membranes to raise efficiency. |
| High | The NASA breadboard needed five manual restarts in 550 hours, four from thermal control and one from water management. | Run a long closed-loop test with redundant thermal control and automatic recovery before flight. |
| High | Only open-loop operation has been shown; gases were vented, not stored and reused. | Add a closed-loop ground test at ≥5 kW for many simulated lunar cycles as a gate before buying flight units. |
| High | Hydrogen crossing into oxygen nears the flammability limit above ~2,000 psia. | Keep storage at or below ~1,800 psia; add hydrogen-in-oxygen sensors and automatic shutdown. |
| High | Mass: 3 MWh of storage is 5–9 t of hardware. | Share tanks and water with the M06 oxygen plant; use modular 25 kW units; let fission carry most of the night. |
| Medium | Tank heating is a large parasitic load in shadow. | Bury or berm tanks; route fuel cell waste heat to them; test whether dry gas tanks can run colder. |
| Medium | Li-ion cells lose capacity sharply in the cold and stop working below about −60 °C. | Keep batteries in heated enclosures inside the habitat or ISRU plant thermal zone. |
| Medium | ISRU water may carry contaminants that poison membranes. | Deionise make-up water; keep the RFC water loop separate except for metered top-ups. |
Specification
| Stored energy | ~3 MWh net (30 kW essential load for 100 h) |
| Fuel cell power | 30 kW continuous in 2 × 25 kW modules (plan design) |
| Round-trip efficiency | ~35% modelled at the south pole; ~80% theoretical maximum |
| Reactants | ~150 kg H₂ + ~1.2 t O₂ from ~1.4 t water (ESTIMATE) |
| Gas pressure | Up to ~12.4 MPa (1,800 psia) |
| RFC mass | 4.6–9.4 t at 320–650 Wh/kg; ~3 t new hardware if ISRU tanks are shared (ESTIMATE) |
| Li-ion buffer | ~100 kWh, ~0.6 t at 160 Wh/kg (plan design) |
| Recharge power | ~29–43 kW of solar over 200–300 h (ESTIMATE) |
| Delivery | Medium lander; tanks may arrive with the M06 oxygen plant |
Sources
- Csank & Scott, NASA GRC: Power and Energy for the Lunar Surface (Apr 2022)
- Cain et al., NASA GRC: Performance of a Regenerative Fuel Cell System for the Lunar Surface (NTRS 20260002730) (Apr 2026)
- Smith et al., NASA GRC: Lunar South Pole Regenerative Fuel Cell System Efficiency Analysis (2022)
- Smith et al., NASA/TM-20210014627: Lunar Equator Regenerative Fuel Cell System Efficiency Analysis (Aug 2022)
- Oleson et al., NASA GRC: A Deployable 40 kWe Lunar Fission Surface Power Concept (NETS 2022) (May 2022)
- JPL: Low-temperature lithium-ion batteries for lunar and planetary missions (poster) (2021)
- Wikipedia: Faraday constant (2026)